Admixture dosage and coverage calculators
Estimates are for site planning. Final dose follows a trial mix and the current TDS. Typical starting dose is about 300 ml per 50 kg cement bag.
- Length 12 m × width 8 m × thickness 150 mm
- Concrete volume 14.40 m³
- Dose 1.5 L per m³
- Admixture 21.6 L
- 1L 22 · 5L 5 · 10L 3 · 20L 2 · 200L 0.11